Model of the Response Function of CUORE Bolometers
(Sprache: Englisch)
Large mass bolometers are used in particle physics experiments to search for rare processes, like neutrinoless double beta decay and dark matter interactions.
In the next years the CUORE experiment (a 1 Ton detector composed by 1000 crystals of TeO2...
In the next years the CUORE experiment (a 1 Ton detector composed by 1000 crystals of TeO2...
Leider schon ausverkauft
versandkostenfrei
Buch
Fr. 160.90
inkl. MwSt.
- Kreditkarte, Paypal, Rechnungskauf
- 30 Tage Widerrufsrecht
Produktdetails
Produktinformationen zu „Model of the Response Function of CUORE Bolometers “
Klappentext zu „Model of the Response Function of CUORE Bolometers “
Large mass bolometers are used in particle physics experiments to search for rare processes, like neutrinoless double beta decay and dark matter interactions.In the next years the CUORE experiment (a 1 Ton detector composed by 1000 crystals of TeO2 operated as bolometers in a large cryostat at 10mK) will be the particle physics experiment with the highest chance of discovering the Majorana neutrino, a long standing and yet fundamental question of particle physics.
The study presented in this book was performed on the bolometers of the CUORE experiment. The response function of these detectors is not linear in the energy range of interest, and it changes with the operating temperature, worsening the performances. The nonlinearity appeared to be dominated by the thermistor and the biasing circuit used to read the bolometer, and was modeled using few measurable parameters.
A method to obtain a linear response is the result of this work. It allows a great improvement of the detector operation and data analysis.
With a foreword by Fernando Ferroni.
Inhaltsverzeichnis zu „Model of the Response Function of CUORE Bolometers “
ForewordAcknowledgements1 Neutrino masses and double beta decay1.1 Oscillations 1.2 Masses 1.3 Double beta decay 1.3.1 Nuclear matrix elements 1.4 Experimental searches for neutrinoless double beta decay 1.4.1 Past and present experiments 1.4.2 Future experiments2 TeO2 bolometric detectors for 0_DBD search2.1 Bolometric detectors 2.1.1 The energy absorber 2.1.2 The choice of TeO2 2.1.3 The sensor 2.1.4 NTD-Ge thermistors 2.2 Bolometer operation 2.3 Arrays of TeO2 bolometers 2.4 Cryogenic setups 2.5 Signal readout 2.5.1 Measurement of the static resistance 2.6 Detector noise 2.7 CUORICINO and CUORE
3 Model of the response function of CUORE bolometers3.1 The CCVR run 3.2 The Model 3.2.1 Thermistor model 3.2.2 Biasing circuit 3.2.3 Bessel filter 3.2.4 Thermal model 3.2.5 Simplified model without temperature dependences 3.2.6 Fit to data 3.2.7 Response function simulation 3.2.8 Amplitude dependence on the working temperature 3.2.9 Extraction of RS from the relationship between amplitude and baseline 4 Thermal response analysis4.1 Data analysis procedure 4.2 The Thermal Response algorithm 4.3 Check of the TR algorithm on MonteCarlo data 4.4 Data analysis 4.4.1 Calibration 4.5 Residual drift in time 4.6 Sources of systematic errors 4.6.1 Choice of the derivative algorithm 4.6.2 Error on the biasing and read-out circuits parameters
5 Thermal response analysis on the Three Towers detector5.1 The Three Towers detector 5.2 Measurements of model parameters 5.2.1 Measurement of V G RS and VS 5.2.2 Measurement of G/GS 5.2.3 Measurement of RL 5.2.4 Measurement of VBGS 5.2.5 Measurement of cp 5.3 Results on calibration data 5.4 Results on background data 5.5 Future developments
6. ConclusionsAppendix A Thermal response analysis on the CCVR detectorAppendix B Precision measurements on the Three Towers detector
Autoren-Porträt von Marco Vignati
Marco Vignati received his Master Degree in Physics from the Università di Roma - La Sapienza in June 2004 with final mark 110/110 cum laude. His degree thesis was entitled "CP asymmetry measurement within b?s transitions with the BaBar experiment" and his supervisors were Prof. Fernando Ferroni and Dr. Gianluca Cavoto. In January 2010 he received his Ph.D. in Physics from the same University under the supervision of Prof. Fernando Ferroni.
Bibliographische Angaben
- Autor: Marco Vignati
- 2011, 120 Seiten, Masse: 16 x 24,1 cm, Gebunden, Englisch
- Verlag: Springer Netherlands
- ISBN-10: 9400712316
- ISBN-13: 9789400712317
- Erscheinungsdatum: 06.05.2011
Sprache:
Englisch
Kommentar zu "Model of the Response Function of CUORE Bolometers"
0 Gebrauchte Artikel zu „Model of the Response Function of CUORE Bolometers“
Zustand | Preis | Porto | Zahlung | Verkäufer | Rating |
---|
Schreiben Sie einen Kommentar zu "Model of the Response Function of CUORE Bolometers".
Kommentar verfassen