Effect of Uneven Cooling on Performance of Air-Cooled Condenser (PDF)
(Sprache: Englisch)
Scientific Essay from the year 2017 in the subject Physics - Thermodynamics, , course: Heat transfer engineering, language: English, abstract: Air-cooled condensers ("ACC") operating in vacuum are widely used at the cold end of contemporary thermal power...
sofort als Download lieferbar
eBook (pdf)
Fr. 13.00
inkl. MwSt.
- Kreditkarte, Paypal, Rechnung
- Kostenloser tolino webreader
Produktdetails
Produktinformationen zu „Effect of Uneven Cooling on Performance of Air-Cooled Condenser (PDF)“
Scientific Essay from the year 2017 in the subject Physics - Thermodynamics, , course: Heat transfer engineering, language: English, abstract: Air-cooled condensers ("ACC") operating in vacuum are widely used at the cold end of contemporary thermal power plants. Proper functioning of the condenser is paramount for power plant efficiency.
To adapt to changing process conditions because of changed ambient air temperature or power station load ACC streets are either taken out of or into service or, module fan speed settings are selected appropriately. Even if all fans are running at same speed local variations of cooling air flow may arise as a consequence of e.g. fan location or local wind impact. The designer must ensure that no negative effect (i.e. no cold spot) may evolve at the steam side of the ACC caused by uneven air side cooling or fan control.
The following note describes a theoretical method to assess the effect of air flow variations on ACC performance and provides simple rules to avoid potentially risky situations. An important role for safe operation plays the size of the secondary condenser. The procedure may be used as a guideline for proper sizing of the secondary condenser with respect to airflow maldistribution.
To adapt to changing process conditions because of changed ambient air temperature or power station load ACC streets are either taken out of or into service or, module fan speed settings are selected appropriately. Even if all fans are running at same speed local variations of cooling air flow may arise as a consequence of e.g. fan location or local wind impact. The designer must ensure that no negative effect (i.e. no cold spot) may evolve at the steam side of the ACC caused by uneven air side cooling or fan control.
The following note describes a theoretical method to assess the effect of air flow variations on ACC performance and provides simple rules to avoid potentially risky situations. An important role for safe operation plays the size of the secondary condenser. The procedure may be used as a guideline for proper sizing of the secondary condenser with respect to airflow maldistribution.
Bibliographische Angaben
- Autor: Hans Georg Schrey
- 2018, 1. Auflage, 21 Seiten, Englisch
- Verlag: GRIN Verlag
- ISBN-10: 366867616X
- ISBN-13: 9783668676169
- Erscheinungsdatum: 04.04.2018
Abhängig von Bildschirmgrösse und eingestellter Schriftgrösse kann die Seitenzahl auf Ihrem Lesegerät variieren.
eBook Informationen
- Dateiformat: PDF
- Grösse: 2.25 MB
- Ohne Kopierschutz
- Vorlesefunktion
Sprache:
Englisch
Kommentar zu "Effect of Uneven Cooling on Performance of Air-Cooled Condenser"
0 Gebrauchte Artikel zu „Effect of Uneven Cooling on Performance of Air-Cooled Condenser“
Zustand | Preis | Porto | Zahlung | Verkäufer | Rating |
---|
Schreiben Sie einen Kommentar zu "Effect of Uneven Cooling on Performance of Air-Cooled Condenser".
Kommentar verfassen